ABOUT ME

-

Today
-
Yesterday
-
Total
-
  • Thermo Orbitrap Eclipse LCMS 매입 매각 합니다.
    매입장비 2024. 12. 27. 09:30

    안녕하세요, 중고분석장비 매입 매각 판매 전문 스카이랩입니다.

     

    스카이랩은 Waters, Agilent, Thermo Fisher, AB Sciex, Perkin Elmer, Shimadzu, Hitachi, JEOL 등과 같은 최고의 분석장비 브랜드들을 취급하고 있으며,

    HPLC, UPLC, GC, LC/MS/MSMS, GC/MS/MSMS, ICP-OES/MS, AAS, FT-IR, UV-VIS, PCR, SEM & TEM 등과 같은 첨단장비를 상시 매입 및 판매하고 있습니다.

     

    오늘은 당사에서 매입하는 Orbitrap Eclipse Tribrid Mass Spectrometer (LCMSMS 액체크로마토그래피 질량분석기)에 대해 소개해드리겠습니다.

    아래 장비에 대한 유휴 장비가 있으시거나 매각을 검토하시는 경우 언제든지 연락 부탁드립니다.

     

    LCMSMS 제품의 경우 국내 최고가로 매입해 드립니다.

     


     

    **Orbitrap Eclipse Tribrid Mass Spectrometer 매입 매각 전문 **

     

     

     

    ▣ Performance specifications

    Orbitrap Mass Range Standard mass range m/z 50–2000, mid-mass range m/z 200–6000, and HMRn mass range m/z 500–8000
    Orbitrap Resolution Standard resolution settings range from 7500 to 500,000 (FWHM) at m/z 200, with isotopic fidelity up to 240,000 FWHM; up to 1,000,000 (FWHM) at m/z 200 with isotopic fidelity up to 240,000 FWHM with 1M option
    Acquisition Rate* Orbitrap MSn acquisition rates up to 40 Hz when measured using a data-dependent experiment with Flex Mix, MS and HCD MS/MS resolution setting of 7500, with a maximum ion fill time of 11 milliseconds; linear ion trap MSn acquisition rates up to 45 Hz using a data dependent experiment with Flex Mix, Orbitrap mass analyzer resolution of 240,000 and HCD MS/MS ion trap detection range of m/z 200–1400, with a MS/MS maximum ion fill time of 10 milliseconds
    Orbitrap Mass Accuracy* External calibration achieves <3 ppm RMS drift over 24 hours, measured with Flex Mix;
    internal calibration achieves <1 ppm RMS drift over 24 hours, measured with Flex Mix
    MS/MS Electrospray Ionization (ESI) Ion Trap Sensitivity 2 µL of a 50 fg/µL solution of reserpine (100 femtograms total) injected at a flow rate of 500 µL/min produces a minimum S/N ratio of 200:1 for the transition of the isolated protonated molecular ions at m/z 609 to the largest two product ions, m/z 397 and m/z 448, when the mass spectrometer is operated at unit resolution in the full scan MS/MS mode, m/z 165–615; the test requires the HESI II probe
    Dynamic Range >5000 within a single Orbitrap mass spectrum
    MS Scan Power Collects MSn , for n = 1 through 10, detected in either the Orbitrap or linear ion trap mass analyzers
    Synchronous Precursor Isolation Samples up to 20 precursors per MSn scan
    Precursor Multiplexing Up to 10 precursors can be multiplexed using the quadrupole mass filter and ion-routing multipole to perform selected ion monitoring or tandem MS
    Polarity Switching One full experimental cycle acquired in
    ETD Option Efficiency Reaction with ETD anions dissociates the isolated 2+ MRFA precursor (m/z 262) to generate a series of fragments that have a summed relative abundance ≥15% to the precursor measured in the linear ion trap, using Flex Mix solution infused at 6 µL/min
    UVPD Option Efficiency Exposure of 100 ms dissociates the isolated Caffeine molecular ion (m/z 195) to generate the m/z 138 product ion with a relative abundance of ≥25% to the precursor measured in the linear ion trap, using Flex Mix solution infused at 6 µL/min
    PTCR Option Efficiency Reaction time of 100 ms causes isolated MRFA 2+ molecular ion (m/z 262) to convert to a charged reduced ion at m/z 524, with a relative abundance of ≥25% to the precursor measured in the linear ion trap, using Flex Mix solution infused at 6 µL/min

     

    Orbitrap Eclipse 외에도 Thermo LCMS 제품은 상시 매입 중이오니, 언제든지 문의 주시기 바랍니다.

    Orbitrap Exploris120
    Orbitrap Exploris240
    Orbitrap Exploris480
    QE HF-X
    Orbitrap Astral

     


     

    HPLC, UPLC, GC, LC/MS/MSMS, GC/MS/MSMS, ICP-OES/MS, AAS, FT-IR, UV-VIS, PCR, SEM & TEM 등
    유휴 중고 분석장비에 대한 구매, 판매, 매각 문의 모두 환영합니다.

    궁금하신 사항이나 문의사항이 있으시면 아래 연락처로 언제든지 연락주시기 바랍니다.

    감사합니다.

     

    스카이랩 ㅣ info@skylab.co.kr ㅣ 031-387-2727

     

Designed by Tistory.